															Overload Relay | โอเวอร์โหลด รีเลย์
| Type | Rating | 1P | 2P | 3P | 4P | 
| iC60N | 1A | A9F74101 | A9F74201 | A9F74301 | A9F74401 | 
| 2A | A9F74102 | A9F74202 | A9F74302 | A9F74402 | |
| 3A | A9F74103 | A9F74203 | A9F74303 | A9F74403 | |
| 4A | A9F74104 | A9F74204 | A9F74304 | A9F74404 | |
| 6A | A9F74106 | A9F74206 | A9F74306 | A9F74406 | |
| 10A | A9F74110 | A9F74210 | A9F74310 | A9F74410 | |
| 16A | A9F74116 | A9F74216 | A9F74316 | A9F74416 | |
| 20A | A9F74120 | A9F74220 | A9F74320 | A9F74420 | |
| 25A | A9F74125 | A9F74225 | A9F74325 | A9F74425 | |
| 32A | A9F74132 | A9F74232 | A9F74332 | A9F74432 | |
| 40A | A9F74140 | A9F74240 | A9F74340 | A9F74440 | |
| 50A | A9F74150 | A9F74250 | A9F74350 | A9F74450 | |
| 63A | A9F74163 | A9F74263 | A9F74363 | A9F74463 | |
| C120N | 80A | A9N18357 | A9N18361 | A9N18365 | A9N18372 | 
| 100A | A9N18358 | A9N18362 | A9N18366 | A9N18374 | |
| 125A | A9N18359 | A9N18363 | A9N18367 | A9N18376 | 
A9N
The Acti9 C60H-DC is a miniature circuit breaker that offers direct current circuit pretection. It protects cricuits against short-circuit currents and overload currents
The Acti9 C60PV-DC is a miniature circuit breaker that is designed for photovoltaic (PV) installations. It protects the cables between each string of a photovoltaic module against short-circuit currents and overload currents.
| DC | |||
| Type | Rating | 1P | 2P | 
| C60H-DC | 1A | A9N61501 | A9N61521 | 
| 2A | A9N61502 | A9N61522 | |
| 3A | A9N61503 | A9N61523 | |
| 4A | A9N61504 | A9N61524 | |
| 6A | A9N61506 | A9N61526 | |
| 10A | A9N61508 | A9N61528 | |
| 16A | A9N61511 | A9N61531 | |
| 20A | A9N61512 | A9N61532 | |
| 25A | A9N61513 | A9N61533 | |
| 32A | A9N61515 | A9N61535 | |
| 40A | A9N61517 | A9N61537 | |
| 50A | A9N61518 | A9N61538 | |
| 63A | A9N61519 | A9N61539 | |
Overload Relay
Thermal relays, coordinated with TeSys D contactors and circuit-breakers, to protect motors up to 150 A (75 kW / 400 V) from overloads
Part of TeSys
TeSys LRD is a flexible range of thermal overload relays from 0.06 kW to 75 kW. Designed for TeSys D contactors ranges, they can be mounted directly under the contactors for compactness or separately using accessories.
| Model | Compatibility | Protection Setting | 
| LRD-01 | D09-D38 | 0.01 – 0.16 | 
| LRD-02 | D09-D38 | 0.16 – 0.25 | 
| LRD-03 | D09-D38 | 0.25 – 0.4 | 
| LRD-04 | D09-D38 | 0.4 – 0.6 | 
| LRD-05 | D09-D38 | 0.63 – 1.00 | 
| LRD-06 | D09-D38 | 1.00 – 1.6 | 
| LRD-07 | D09-D38 | 1.6 – 2.5 | 
| LRD-08 | D09-D38 | 2.5 – 4 | 
| LRD-10 | D09-D38 | 4 – 6 | 
| LRD-12 | D09-D38 | 5.5 – 8 | 
| LRD-14 | D09-D38 | 7 – 10 | 
| LRD-16 | D12-D38 | 9 – 13 | 
| LRD-21 | D18-D38 | 12 – 18 | 
| LRD-22 | D25-D38 | 17 – 25 | 
| LRD-32 | D25-D38 | 23 – 32 | 
| LRD-35 | D32-D38 | 30 – 38 | 
| LRD-340 | D40A-D65A | 30 – 40 | 
| LRD-350 | D40A-D65A | 37 – 50 | 
| LRD-365 | D40A-D65A | 48 – 65 | 
| LRD-3363 | D65-D95 | 63 – 80 | 
| LRD-3365 | D80-D95 | 80 – 104 | 
| LRD-4367 | D115-D150 | 95 – 120 | 
| LRD-4369 | D150 | 110 – 140 | 